Fieldbus Cables

Fieldbus Cables

Fieldbus cables are designed to withstand the destructive conditions commonly found in industrial applications, such as temperature extremes, umidity/moisture, dust and oil. Invest in cable with proven performance and reliability to significantly reduce system failures and avoid costly downtime.

Conductor


Warning: Undefined variable $output in /home/almousacables/www/www/wp-content/themes/profiletree/functions.php on line 193

Construction

FF cable , FIELDBUS CABLE , FF844

Conductor

Plain or tinned copper to class 1 or class 2or class 5 to IEC 60228. 18 AWG,16AWG,1.0mm2, 1.5 mm2

Insulation

XLPE according to EN 50290-2-29.

Color code

Black , white for pairs or any other color code that is required by the customers.

Pair

Two insulated conductors twisted

Pair shielding

Each pair is shielded with aluminum mylar tape with a tinned copper drain wire

Assembly

Several shielded pairs are assembed to for a cable core and shielded with a tinned copper drain wire to provide etectostatic shield.

Inner sheath option

For armored cables a flame retardant PVC inner jacket is extruded over the cable core under the armor.LSHF option is available upon request.

Environmental protection

Lead sheath or a multilayer sheath AL/HDPE/PA in accordance with BS EN 50288-7 is avilable for direct burial application as a hydrocarbon protection.

Armor

Galvanized steel wire or galvanised steel wire braid or galvanised steel tape armor option is available.

Outer jacket

Flame retardant PVC to EN 50290-2-21 or UL13 or LSHF to EN 50290-2-26.

Print on the outer sheath (Example)

FF Cable IEC61158-2 Type A FF844 STP Type PLTC(UL)EXXXXXX 12Pr18 AWG(0.82 mm2) sun res dir bur oil res I 90C meter mark

Standards

FF844,IEC 61158-2,BS EN 50288-7, EN 50290-2-21, EN 50290-2-26, EN 50290-2-29, IEC 60332-3-24, ICEA S-73-532 , UL 1581 SECTION 1200, IEC 61034, I3C 60754-1 & 2, UL13

Technical Data


Warning: Undefined variable $output in /home/almousacables/www/www/wp-content/themes/profiletree/functions.php on line 222

Temperature range

90C, 105C

Voltage Grade

300V UL 13 & 500 V BS EN 50288-7 or 600 V (for unarmored cables only Type TC UL 1277)

Flame retardance

IEC 60332-3-24, IEC 60331

Oil resistance

ICEA S-73-532 or oil res I of UL13 or oil res II of UL13

Sunlight resistance

UL 1581 SECTION 1200

Impedance

100 Ω ± 20 Ω

Attenuation at f=39 KHz, Max

3 dB/Km

Propagation delay change( f=7.9-39 KHz), Max

1.7 µs/Km