Conductor
tinned copper to class2 or class 5 to IEC 60228.
Insulation
Halogen free croxxlinked insulation. GP4 to BS 7655-1.2 or HX to IEC 60092.For fire resistance option a MICA tape is wrapped over the conductor
Color code
Black , white for pairs , black, white and red for triads or customized as required.
Pair/Triad
Two insulated conductors twisted or three insulated conductors twised to form a triad.
Pair/Triad shielding option
Oiptionally ,Each pair or triad is shielded with aluminum mylar tape with a tinned copper drain wire for electrostatic shielding for analog applications.
Assembly
Several pairs/triads or shielded pairs/triads are assembed to for a cablke core and optionally shielded with a tinned copper drain wire to provide etectostatic shield.
Inner sheath option
Flame retardant halogen free thermoplastic or thermosetting material.Type SW4 to BS 7655-2.6
Armor
Tinned copper wire braid or bronze braid.
Outer jacket
Flame retardant halogen free thermoplastic or thermosetting material.Type SW4 to BS 7655-2.6. Mud resistance option available.
Print on the outer sheath (Example)
Fire Res CU/MGT/XLPE/LSHF/SWA/LSHF xxTRXxx mm² ISOS 300V
Standards
IEC 60092-360, IEC 60092-376, IEC 60028, IEC 60754 , BS 7655-1.2, BS 7655-2.6 , IEC 60332-3-22, IEC 60331, BS 6387, NEK TS 606