Tray Cables UL TC

Tray Cables UL TC

Tray cables, specifically those with UL Type TC or TC-ER designations, are designed for use in cable tray systems. TC cables are typically used in power and control applications within industrial settings, while TC-ER cables are designed for exposed runs within the tray. The “ER” designation allows for a limited length of unsupported cable outside the tray

Tray Cables (UL type TC and TC-ER) are used in various control and power of applications and industries where cable tray systems are installed for routing and support. These cables are often exposed, therefore pass more stringent requirements under UL 1277, the standard for power and control tray cables. Proper installations will see 300V rated tray cables separated within the tray from 600V rated tray cables. UL Listings that contain “-ER” permit the cable to exit the cable tray unsupported for a length of six feet.  Right Hand Industrial supplies a wide range of flexible tray cable as well as high flexing tray cable including VNTC, TC, TC-ER, PLTC, PLTC-ER, ITC, ITC-ER and WTTC rated cables.

Conductor


Warning: Undefined variable $output in /home/almousacables/www/www/wp-content/themes/profiletree/functions.php on line 193

Conductor

Plain or tinned copper to ASTM class B or classC or class K.

Insulation

flame retardant Polyvinyl chloride or flame retrdant XLPE or MICA glass tape + flame retardnt XLPE according to UL1581 or UL type THHW or XHHW type conductors.

Color code

Black with numbers or as required by the customer specification.

Assembly

insulated conductors assembled. An electroststic shield over the assembly or group of insulated conductors available upon request.

Outer jacket

Flame retardant PVC or LSHF or FRXLPE or CPE oil resistance and sunlight resistance options according to UL 13 or UL 1277.

Print on the jacket (Example)

Type TC(UL)EXXXXXX 600V 90Cdry/75C wet** 12Pr18 AWG(0.82 mm2) I&O shielded sun res dir bur oil res I or II meter mark

Standards

UL 1277, UL83, UL44, UL 1685 , UL1581 and ASTM, IEC 60332-3-24 & IEC 60331

Technical Data


Warning: Undefined variable $output in /home/almousacables/www/www/wp-content/themes/profiletree/functions.php on line 222

Temperature range

70C, 90C, 105C

Voltage Grade

600 VOLT

Flame retardance

Vertical tray flame test

Oil resistance

UL1277

Sunlight resistance

720 hrs